Category of Content
Siting Experience Documents Only
Publication Date
Keywords
Lessons Learned from the West Valley Spent Nuclear Fuel Shipment within the United States
Lessons Learned from the West Valley Spent Nuclear Fuel Shipment within the United States
This paper describes the lessons learned from the U.S. Department of Energy (DOE) transportation of
125 DOE-owned commercial spent nuclear fuel (SNF) assemblies by railroad from the West Valley Demonstration
Project to the Idaho National Engineering and Environmental Laboratory (INEEL). On July 17, 2003, DOE made
the largest single shipment of commercial SNF in the history of the United States. This was a highly visible and
political shipment that used two specially designed Type B transportation and storage casks. This paper describes
Recommendations Related to Browns Ferry Fire (NUREG-0050)
Recommendations Related to Browns Ferry Fire (NUREG-0050)
On March 22, 1975, a fire was experienced at the Browns Ferry Nuclear Plant near Decatur, Alabama. The Special Review Group was established by the Executive Director for Operations of the Nuclear Regulatory Commission (NRC) soon after the fire to identify the lessons learned from this event and to make recommendations for the future in the light of these lessons. Unless further developments indicate a need to reconvene the Review Group, its task is considered complete with the publication of this report.
Safety Evaluation for Operation of Browns Ferry, Units 1 and 2, Following the March 22, 1975 Fire (NUREG-0061, Initial Report)
Safety Evaluation for Operation of Browns Ferry, Units 1 and 2, Following the March 22, 1975 Fire (NUREG-0061, Initial Report)
On March 22, 1975, a fire at the Browns Ferry Nuclear Plant caused a shutdown of Units 1 and 2. The facility subsequent to the shutdown was found to have incurred substantial damage to power, control, and instrumentation wiring. All three units are presently in the shutdown condition with the fuel removed from the vessels for Units 1 and 2; the Unit 3 reactor is still under construction with operation for that unit scheduled for early 1976.
Report to Congress on Abnormal Occurrences (NUREG-0090)
Report to Congress on Abnormal Occurrences (NUREG-0090)
Section 208 of the Energy Reorganization Act of 1974, as amended (Public Law 93-438), defines an "abnormal occurrence" (AO) as an unscheduled incident or event that the U.S. Nuclear Regulatory Commission (NRC) determines to be significant from the standpoint of public health or safety. The Federal Reports Elimination and Sunset Act of 1995 (Public Law 104-66) requires that the NRC report AOs to Congress annually.
Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition (NUREG-75/087)
Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition (NUREG-75/087)
The Standard Review Plan (SRP) is prepared for the guidance of staff reviewers in the Office of Nuclear Reactor Regulation in performing safety reviews of applications to construct or operate nuclear power plants. The principal purpose of the SRP is to assure the quality and uniformity of staff reviews, and to present a well-defined base from which to evaluate proposed changes in the scope and requirements of reviews.
Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants: A Guidance Manual for Users of Standard Technical Specifications (NUREG-0133)
Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants: A Guidance Manual for Users of Standard Technical Specifications (NUREG-0133)
This guidance manual provides the NRC staff methodology for calculating parameters for limiting conditions of operation required in the radiological effluent Technical Specifications for light-water-cooled nuclear power plants. it provides guidance in using the model specifications reported in NUREG-0472 (Revision 1)*, and NUREG-0473 (Revision 1)*, applicable to operating PWR and BWR licensees, and users of the Standard Technical Specifications packages available for various vendor designs.
Recommendations for PWR Storage and Transportation Casks That Use Burnup Credit
Recommendations for PWR Storage and Transportation Casks That Use Burnup Credit
Regulatory Perspective on Potential Fuel Reconfiguration and Its Implication to High Burnup Spent Fuel Storage and Transportation
Regulatory Perspective on Potential Fuel Reconfiguration and Its Implication to High Burnup Spent Fuel Storage and Transportation
The recent experiments conducted by Argonne National Laboratory on high burnup fuel cladding material property show that the ductile to brittle transition temperature of high burnup fuel cladding is dependent on: (1) cladding material, (2) irradiation conditions, and (3) drying-storage histories (stress at maximum temperature) [1]. The experiment results also show that the ductile to brittle temperature increases as the fuel burnup increases.
Burnup Credit — Contribution to the Analysis of the Yankee Rowe Radiochemical Assays
Burnup Credit — Contribution to the Analysis of the Yankee Rowe Radiochemical Assays
This report presents a methodology for validation of the isotopic
contents of spent light water reactor fuel for actinide-only burnup
credit with additional high-quality radiochemistry assay (RCA) data
obtained from the Yankee Rowe pressurized water reactor. The
additional Yankee Rowe RCA data were not included in previous
isotopic validation studies for burnup credit due to the difficulty of
accurately modeling the complex Yankee Rowe fuel assembly design
using the SAS2H one-dimensional sequence of the earlier SCALE
Impacts Associated with Transfer of Spent Nuclear Fuel from Spent Fuel Storage Pools to Dry Storage After Five Years of Cooling
Impacts Associated with Transfer of Spent Nuclear Fuel from Spent Fuel Storage Pools to Dry Storage After Five Years of Cooling
In order to decrease the risk of terrorism, it has been suggested that used nuclear fuel should be
moved to dry storage early, after five years cooling in the spent fuel pool. The Nuclear
Regulatory Commission (NRC) has reviewed this issue and issued a white paper stating that it
did not believe such a measure was justified in light of additional security measures implemented
at nuclear plants and the impacts associated with the early movement of used fuel into dry
Sensitivity and Uncertainty Analysis of Commercial Reactor Criticals for Burnup Credit
Sensitivity and Uncertainty Analysis of Commercial Reactor Criticals for Burnup Credit
This paper provides insights into the neutronic similarities between a representative high-capacity rail-transport cask containing typical pressurized water reactor (PWR) spent nuclear fuel assemblies and critical reactor state-points, referred to as commercial reactor critical (CRC) state-points. Forty CRC state-points from five PWRs were analyzed, and the characteristics of CRC state-points that may be applicable for validation of burnup-credit criticality safety calculations for spent fuel transport/storage/disposal systems were identified.
Review of Yucca mountain Disposal Criticality Studies
Review of Yucca mountain Disposal Criticality Studies
Review of Results for the OECD/NEA Phase VII Benchmark: Study of Spent Fuel Compositions for Long-Term Disposal
Review of Results for the OECD/NEA Phase VII Benchmark: Study of Spent Fuel Compositions for Long-Term Disposal
Actinide-Only Burnup Credit for Pressurized Water Reactor Spent Nuclear Fuel - I: Methodology Overview
Actinide-Only Burnup Credit for Pressurized Water Reactor Spent Nuclear Fuel - I: Methodology Overview
A conservative methodology is presented that would allow taking credit for burnup in the criticality safety analysis of spent nuclear fuel (SNF) packages. The method is based on the assumption that the isotopic concentration in the SNF and cross sections of each isotope for which credit is taken must be supported by validation experiments. The method allows credit for the changes in the 234U, 235U, 236U, 238U, 238Pu, 239Pu, 240Pu, 241Pu, 242Pu, and 241Am concentration with burnup. No credit for fission product neutron absorbers is taken. The methodology consists of five major steps:
Actinide-Only Burnup Credit for Pressurized Water Reactor Spent Nuclear Fuel - III: Bounding Treatment of Spatial Burnup Distributions
Actinide-Only Burnup Credit for Pressurized Water Reactor Spent Nuclear Fuel - III: Bounding Treatment of Spatial Burnup Distributions
A flat, uniform axial burnup assumption, preferred for its computational simplicity, does not always conservatively estimate the pressurized water reactor spent-fuel-cask multiplication factors. Rather, the reactivity effect of the significantly underburned fuel ends, usually referred to as the "end effect," can be properly treated by explicit modeling of the axial burnup distribution based on limiting axial burnup profiles.
Actinide-Only Burnup Credit for Pressurized Water Reactor Spent Nuclear Fuel - II: Validation
Actinide-Only Burnup Credit for Pressurized Water Reactor Spent Nuclear Fuel - II: Validation
The calculation of isotopic concentrations in spent nuclear fuel (SNF) assemblies and the subcritical multiplication factor of SNF packages are two of the essential requirements of the actinide-only burnup credit methodology. To justify the accuracy of the computed values, the code systems used to perform the calculations must be validated. Here, the techniques used for actinide-only burnup credit isotopic and criticality validation are presented and demonstrated.
Use of Reactor-Follow Data to Determine Biases and Uncertainties for PWR spent Nuclear Fuel
Use of Reactor-Follow Data to Determine Biases and Uncertainties for PWR spent Nuclear Fuel
Modeling BWR Spent-Fuel Isotopics with SAS2H and CASMO-3
Modeling BWR Spent-Fuel Isotopics with SAS2H and CASMO-3
Effects of Integral Burnable Absorbers on PWR Spent Nuclear Fuel
Effects of Integral Burnable Absorbers on PWR Spent Nuclear Fuel
Spent Fuel Burnup Credit in Casks: An NRC Perspective
Spent Fuel Burnup Credit in Casks: An NRC Perspective
Until now, the Nuclear Regulatory Commission's (NRC) approval of criticality safety evaluations for spent fuel in transport and storage casks has been based on analyzing the fuel as though it were fresh and without burnable poisons. The well-known nuclide composition of fresh fuel has provided a straightforward and bounding approach for showing that spent fuel systems will remain subcritical under normal and accident conditions. Burnup credit refers to the approval of criticality safety evaluations that consider the decrease in fuel reactivity caused by. irradiation in the reactor.
Selection of Reactor Criticals as Benchmarks for Spent Nuclear Fuels
Selection of Reactor Criticals as Benchmarks for Spent Nuclear Fuels
An Empirical Approach to Bounding the Axial Reactivity Effects of PWR Spent Nuclear Fuel
An Empirical Approach to Bounding the Axial Reactivity Effects of PWR Spent Nuclear Fuel
One of the significant issues yet to be resolved for using
burnup credit ~BUC! for spent nuclear fuel ~SNF! is establishing
a set of depletion parameters that produce an adequately conservative
representation of the fuel’s isotopic inventory. Depletion
parameters ~such as local power, fuel temperature, moderator temperature,
burnable poison rod history, and soluble boron concentration!
affect the isotopic inventory of fuel that is depleted in a
pressurized water reactor ~PWR!. However, obtaining the detailed
Nondestructive Assay of Nuclear Low-Enriched Uranium Spent Fuels for Burnup Credit Application
Nondestructive Assay of Nuclear Low-Enriched Uranium Spent Fuels for Burnup Credit Application
Criticality safety analysis devoted to spent-fuel storage and transportation has to be conservative in order to be sure no accident will ever happen. In the spent-fuel storage field, the assumption of freshness has been used to achieve the conservative aspect of criticality safety procedures. Nevertheless, after being irradiated in a reactor core, the fuel elements have obviously lost part of their original reactivity. The concept of taking into account this reactivity loss in criticality safety analysis is known as burnup credit.