Skip to main content

Criticality Evaluation of Plutonium Disposition Ceramic Waste Form: Degraded Mode

Author(s)
CRWMS
Publication Date

Abstract

Thep purpose of this calculation is to perform degraded mode criticality evaluations of plutonium disposed in a ceramic waste form and emplaced in a Monitored geologic Repository (MGR). A 5 Defense High-Level Waste (DHLW) Canister Waste Package (WP) design, incorporating the can-in-canister concept for plutonium immobilization is considered in this calculation. Each HLW glass pour canister contains 7 tubes. Each tube contains 4 cans, with 20 ceramic disks (immobilized plutonium) in each. The criticality evaluations estimate the values of the effective neutron multiplication factor, Keff, for different degraded internal WP configurations.

Community
Category of Content
Associated Sites