Abstract
Target accuracy on LWR neutronics parameters is 2 to 5 times lower than the a priori uncertainty (1σ)
due to nuclear data. This paper summarizes the experimental facilities and the integral measurements that are required
for code qualification. The rigorous use of integral information through trend analysis method is described. Trends
on JEF2 data from Keff measurements and P.I.Es are presented. These trends were accounted for in the new JEFF3
evaluations. The role of fundamental experiments, such as worth measurement of separated isotopes, is emphasized.
Some recent improvements in JEFF3.1 (237Np, 239Pu) are extracted from these specific experiments.
Additional Information
in Proceedings of the International Conference on Nuclear Data for Science and Technology 2007