Reactor Record Uncertainty Determination

The objective of this calculation is to evaluate commercial spent nuclear fuel (CSNF) bumup uncertainty based on pressurized water reactor (PWR) and boiling water reactor (BWR) records kept by each utility. The bumup uncertainties will be used to adjust either the waste package loading curves or the bumup values of assemblies shipped to the repository.
This engineering calculation supports the burnup credit methodology in Reference 1 and is performed in accordance with the AREVAIFANP procedures in References 2 and 3.

Isotopic Generation and Confirmation of the BWR Appl. Model

The objective of this calculation is to establish an isotopic database to represent commercial spent nuclear fuel (CSNF) from boiling water reactors (BWRs) in criticality analyses performed for the proposed Monitored Geologic Repository at Yucca Mountain, Nevada. Confirmation of the conservatism with respect to criticality in the isotopic concentration values represented by this isotopic database is performed as described in Section 3.5.3.1.2 of the Disposal Criticality Analysis Methodology Topical Report (Reference 7.1).

CRC Depletion Calculations for Quad Cities Unit 2

The purpose of this calculation is to document the Quad Cities Unit 2 boiling water reactor (BWR) fuel depletion calculations performed as part of the commercial reactor critical (CRC) evaluation program. The CRC evaluations constitute benchmark calculations that support the development and validation of the neutronics models used for criticality analyses involving commercial spent nuclear fuel in a geologic repository. The revision of this calculation incorporates control blade effects and minor variations in the SAS2H assembly modeling.

CRC Depletion Calculations for LaSalle Unit I

The purpose of this calculation is to document the LaSalle Unit 1 boiling water reactor (BWR) fuel depletion calculations performed as part of the commercial reactor critical (CRC) evaluation program. The CRC evaluations constitute benchmark calculations that support the development and validation of the neutronics models used for criticality analyses involving commercial spent nuclear fuel in a geologic repository. This calculation incorporates control blade effects and minor variations in the SAS2H assembly modeling.

SAS2H Analysis of Radiochemical Assay Samples From Cooper BWR Reactor

The purpose of this design analysis is to determine the accuracy of the SAS2H module of SCALE 4.3 in predicting isotopic concentrations of spent fuel assemblies. The objective is to develop a methodology for modeling assemblies similar to those evaluated within this analysis and to establish the consistency of SAS2H predictions. The results of this analysis may then be applied to future depletion calculations using SAS2H in which no measurements are available. The analytical model employed for this analysis was the SAS2H module of the SCALE sequence.

Radiation Effects of Isotopic Uncertainty for Burnup Credit Validation

The objective of this calculation is to provide the uncertainty term for fission product and minor actinides which contributes to the determination of the critical limit for burnup credit calculations. The scope of this calculation covers PWR and BWR spent nuclear fuel. This activity supports the Criticality Department's validation of burnup credit. The intended use of these results is in future Criticality Department calculations and analyses.

Review and Prioritization of Technical Issues Related to Burnup Credit for BWR Fuel

This report has been prepared to support technical discussion of and planning for future
research supporting implementation of burnup credit for boiling-water reactor (BWR) spent fuel
storage in spent fuel pools and storage and transport cask applications. The review and
discussion in this report are based on knowledge and experience gained from work performed
in the United States and other countries, including experience with burnup credit for
pressurized-water reactor (PWR) spent fuel. Relevant physics and analysis phenomena are

Disclaimer: Note that this page contains links to external sites. When leaving the CURIE site, please note that the U.S. Department of Energy and Pacific Northwest National Laboratory do not control or endorse the content or ads on these sites.