MCNP Evaluation of Laboratory Critical Experiments: Homogeneous Mixture Criticals

The purpose of this analysis is to document Waste Package Development Department (WPPD) MCNP evaluations of benchmark solution Laboratory Critical Experiments (LCE's). The objective of this analysis is to quantify the ability of the MCNP 4A (Reference 5.4) code system to accurately calculate the effective neutron multiplication factor (keff) for various measured critical (i.e., keff=1.0) configurations.