The purpose of this calculation is to perform degraded mode criticality evaluations of Plutonium disposed in a ceramic waste form and emplaced in a Monitored Geologic Repository (MGR). A 5 Defense High-Level Waste (DHLW) Canister Waste Package (WP) design, incorporating the can-in-canister concept for Plutonium immobilization is considered for this calculation. Each HLW glass pour canister contains 7 tubes. Each tube contains 4 cans, with 20 ceramic disks (immobilzed Plutonium) in each. The criticality evaluations estimate the values of the effective neutron multiplication factor, k-effective, for different degraded internal WP configurations.